Registered User
Log On

Customer Focus
Articles
Sitemap
Helpline
Enquiries

 

400V Specifications

500V Specifications

INPUT

Input supply voltages

60-140A:   230Vac to 480Vac
170-700A: 380Vac to 480Vac
Input supply phases 3 phase, 3 wire, earthed neutral
Input supply tolerance -20% to +15%
Input frequency range 48 to 62Hz
Input current < output current
Input displacement factor >0.99
Input current THD <40%
Power loss ride through > 2 seconds at rated voltage

OUTPUT

Output voltage to motor 0 to Vin -15V @ 100% load
Current overload capability 150% for 30 secs at 50°C
150% for 60 secs at 40°C
Frequency range 0 to ±400Hz (V/Hz)
0 to ±100Hz (flux vector)
Efficiency (full load, 50Hz) >97%
Suit motor rated voltages 5 to 500Vac
Suit motor rated frequencies 10 to 400Hz
Modulation method Space Vector modulation
Modulation frequency Up to 10kHz Whisper Wave or Narrow Band

ENVIRONMENTAL

Protection standard IP54 / NEMA 12 (Electronics enclosure only for 170-700A) 
Operating temperature 0°C to 50°C
Storage temperature -40°C to +80°C
Relative humidity <90%, noncondensing
Altitude 1000m
Altitude derating (>1000m) -1% per 100m; 3000m max.

DRIVE PROTECTION

Supply loss Input phase loss
Software thermal model Heatsink overheat
IGBT overload Internal air overheat
Output current limit Overcurrent trip
DC bus voltage limiting Ground fault
Short circuited load Regeneration limit
Low DC bus voltage
Hardware failure

MOTOR AND DYNAMIC BRAKE PROTECTION

Motor thermal model trip PTC thermistor trip
Overload warning Shear pin trip (configurable)

Dynamic brake resistor thermal model trip

Torque limit and time-out (configurable)

Speed limit and time-out (configurable)

CONTROL

Control method Flux vector or V/Hz control
Analogue inputs 2 inputs, configurable as 0-10 Vdc,
±10Vdc, 4-20mA or 0-20mA
Digital inputs 6 configurable inputs plus 1 PTC or trip input
Analogue outputs 2 outputs, configurable as 0-10Vdc, ±10Vdc, 4-20mA or 0-20mA
Relay outputs 1 changeover, 2 normally open, rated 230Vac or 30Vdc, 2A non-inductive

DIMENSIONS

Item Reference

 H
mm (inches)
W
mm (inches) 
 D
mm (inches)

Weight
kg (lbs.)

UE060C54

970 (38) 347 (13) 313 (12)

90 (198)

UE075C54

970 (38) 347 (13) 313 (12)

90 (198)

UE090C54

970 (38) 347 (13) 313 (12)

94 (213)

UE115C54

970 (38) 347 (13) 313 (12)

97 (213)

UE140C54

970 (38) 347 (13) 313 (12)

97 (213)

UE170C54

1426 (56) 545 (21.5) 412 (16)

160 (353)

UE205C54

1426 (56) 545 (21.5) 412 (16)

175 (386)

UE250C54

1426 (56) 545 (21.5) 412 (16)

175 (386)

UE305C54

1426 (56) 965 (38) 412 (16)

320 (705)

UE370C54

1426 (56) 965 (38) 412 (16)

320 (705)

UE440C54

1426 (56) 965 (38) 412 (16)

350 (772)

UE540C54

1426 (56) 965 (38) 412 (16)

350 (772)

UE620C54

1426 (56) 1385 (54.6) 412 (16)

566 (1248)

UE700C54

1426 (56) 1385 (54.6) 412 (16)

566 (1248)

 

Model selection Guide

One drive fits all applications
Exceptional Performance
Suitable for harsh industrial environments
Installation Flexibility
Control Flexibility
Certified and Approved CE
PDL and Schindler Lifts - A winning team at Eden Park
Applications
 
Product Overview
 
Support Documentation

 

 

 

 

 

Enclosure
Rating
Frame

Item Reference

@50°C

@40°C

A
(Note 2)

Motor kW
400V
(Note3)

Motor HP
460V
(Note3)

Motor HP
230V
(Note3)

A
F>25Hz 
(Note 4)

Motor kW
400V (Note3)

Motor HP
460V (Note3)

Motor HP
230V (Note3)

Nema 12 Electronics Enclosure IEC IP54

4

UE060C54

60

30

40

20

75

37

60

25

UE075C54

75

37

60

25

94

55

75

30

UE090C54

90

45

75

30

112

55

75

40

UE115C54

115

55

75

40

144

75

100

50

UE140C54

140

75

100

50

175

90

150

60

IEC IP54 Electronics Enclosure

5

UE170C54

170

90

150

75

205

110

150

75

UE205C54

205

110

150

75

250

132

200

100

UE250C54

250

132

200

100

305

150

250

125

6

UE305C54

305

160

250

125

370

200

300

150

UE370C54

370

200

300

150

440

250

350

150

UE440C54

440

250

350

150

540

300

450

200

UE540C54

540

300

450

200

620

355

500

250

7

UE620C54

620

355

500

250

700

400

600

300

UE700C54

700

400

600

300

850

500

700

350

Note:   Supply type - 3 phase earthed neutral.
           Frame 4 is UL/cUL approved for 230 and 440 - 480Vac. 230V option must be specified at time of order. 
           Frames 5 to 7 are UL/cUL approved for 380 - 500Vac. 230V options are available, please consult factory. 
Note 2: Current rating is constant across the voltage range specified.
Note 3: Power ratings are based on typical 4 - pole ratings only. Check your motor specification before selecting. 
Note 4: Decrease linearly to 0Hz.