Specifications
|
INPUT
|
| Input
supply voltages |
1~ 200Vac -
250Vac
3~ 200Vac - 250Vac
3~ 200Vac - 480Vac
(3-wire earthed neutral) |
| Input
frequency range |
48 - 62Hz |
| Input
displacement factor |
>0.99 |
| Power
loss ride through |
>1 second |
|
OUTPUT
|
| Output
Voltage to Motor |
< Vin |
| Electrical efficency |
>0.97% (full load, 50Hz) |
| Current overload capability |
150% for 30 secs (when hot) |
| Frequency range |
0 to ±150Hz |
| Modulation method |
Space vector modulation |
| Modulation frequency |
Up to 8kHz Whisper Wave or Narrow Band |
|
ENVIRONMENTAL
|
| Protection
standard |
IP20
Enclosure
IP54 Display Unit
Pollution Degree 2 |
| Operating
temperature |
0°C
to 50°C |
| Storage
temperature |
-40°C
to 80°C |
| Relative
humidity |
<90%,
noncondensing |
| Altitude |
1000m |
| Altitude
derating (>1000m) |
-1%
per 100m; 3000m max. |
|
CONTROL
|
| Control
method |
Dynamic
Scalar Control |
| Digital
inputs |
5
configurable inputs |
| Analogue
inputs |
2
inputs, 1 dedicated 4-20mA,
1 configurable as 0-10V,±10V |
| Analogue
outputs |
1
output configurable as 4-20mA
or 0-10V or ±10V |
| Relay
outputs |
1
changeover, 1 normally open,
rated 250Vac or 30Vdc,
2A non-inductive |
|
Comprehensive drive, motor, and
thermal modelling
RS232/485 Serial Communications
option.
|
| |
|
DIMENSIONS
|
|
Current
|
H
(mm) |
W (mm) |
D
(mm) |
|
2.5 / 4 / 7
|
242 |
97 |
216 |
|
9 / 12 / 16
|
242 |
135 |
216 |
Specifications are
subject to change without notice. |
Model Selection Guide
|
|