690 Specifications

INPUT

Supply Voltage 690Vac
Supply Phases 3 phase, 3 wire, earthed neutral
Supply Tolerance -20% to +5%
Frequency Range 50(60Hz option)
Current £ Output Current
Displacement Factor ³ 0.95
Distortion Factor £ 0.88
Power Loss Ride Through > 2 seconds at rated voltage

OUTPUT

Voltage 0 to Vin
Frequency Range 0 - 100Hz
Efficiency (at rated load) >97% @ 2kHz switching
>96% @ 4kHz switching
Control Method Vectorque (True Sensorless Vector)
Current Overload Capacity Rated Models: 150% for 30 secs @ 50oC/2kHz;
40oC/4kHz
125% for 30 secs @ 40oC/2kHz;
30oC/4kHz

ENVIRONMENTAL

Protection Standard  IP20
Operating Temperature 0°C - 50°C

Temperature Re-rating of 
output current 

120% @ 40oC/2kHz or 30oC/4kHz
Altitude 1000m
Altitude De-rating (>1000m) -1 per 100m; 3000m max.
Relative Humidity  <90%, non-condensing

DRIVE / MOTOR PROTECTION

Inverter thermal, voltage & short circuit
Motor 500V/µs dV/dt filter, thermal protection, ground fault, phase loss, motor PTC

CONTROL

Control Method Vectorque (True Sensorless Vector) 
Analogue Inputs 2 inputs, configurable as +10Vdc,
4 - 20mA

Digital Inputs

6 configurable inputs plus 1 PTC or trip input

Analogue Outputs

2 outputs configurable as + 10Vdc,
4 - 20mA

Digital Outputs

2 High Speed Open Collector

Relay Outputs

3 configurable change over relays, 230Vac or 24 Vdc, 1 Amp non-inductive

SERIAL COMMUNICATION OPTIONS

Standard RS232
Optional Isolated RS485, Device Net, Profibus – DP, Modbus, Modbus plus, Interbus, Remote I/O

ELECTROMAGNETIC COMPATIBILITY

The Microdrive V Series complies with the following EMC standards: EN61800-3; 1996 (Adjustable speed electrical power drive systems).
The Micordrive V Series is CE and C-tick certified.

Model Selection Guide

Precise Control Compact Design
Exceptional Performance
Installation Flexibility
Control Flexibility
Comprehensive Protection
System Design Options
 
Applications
 
Microdrive V Product Overview
 
Support Documentation

 

 

 

 

 

Model

Output Current
@50 C, 2kHz
(150% O/L)*

Output Current
@40 C, 2kHz
(125% O/L)*

Overload Current  Typical Motor Rating**
 (150% O/L)
Typical Motor Rating**
 (125% O/L)
MV100E20

100A

120A 150A 90KW 110KW
MV167E20

167A

200A 250A 160KW 200KW
MV200E20

200A

240A 300A 200KW 250KW
MV300E20

300A

360A 450A 250KW 315KW
MV400E20

400A

480A 600A 400KW 500KW
MV500E20 500A 600A 750A 500KW 560KW
MV600E20 600A 720A 900A 560KW 630KW

*2kHz switching frequency @610: SWFREQ = LOW
** Typical value only: Refer to motor numeplate current and compare with drive rated current. 

Dimesions

Model

Height
(mm)
Width
(mm) 
Cut out
(mm)
Depth
(mm)

Weight
 (kg)

Gland Plate Width
 (kg)
Airflow m3/min Power Loss kW*
MV100E20 1260 248 218 440 85 198 6 3.4
MV167E20 1260 488 458 440 170 438 18 5
MV200E20 1260 488 458 440 170 438 18 6
MV300E20 1260 728 698 440 255 678 24 9
MV400E20 1260 968 938 440 340 918 30 12
MV500E20 1260 1208 1178 440 425 1158 36 15
MV600E20 1260 1448 1418 440 510 1398 42 18

* Power loss at 50C rated current