400v Specifications

500V Specifications

INPUT

Input supply voltages 208 to 230Vac or 380 to 440Vac
Input supply phases 3 phase, 3 wire, earthed neutral
Input supply tolerance -10% to +10%
Input frequency range 48 to 62Hz
Input current < output current
Input displacement factor > 0.99
Input current THD < 40%
Power loss ride through > 2 seconds at rated voltage

OUTPUT

Output voltage to motor 0 to Vin -3V @ 100% load
Current overload capability CT: 150% for 30 secs at 50°C
      150% for 60 secs at 40°C
VT: 120% for 60 secs at 40°C
Frequency range 0 to ±400Hz (max)
Efficiency (full load, 50Hz) > 97%
Suit motor rated voltages 5 to 500Vac
Suit motor rated frequencies 10 to 400Hz
Modulation method Space Vector modulation
Modulation frequency Up to 16kHz Whisper Wave or Narrow Band

ENVIRONMENTAL

Protection standard Enclosure, IP54/NEMA 12
Operating temperature 0°C to 50°C
Storage temperature -25°C to +80°C
Relative humidity <90%, noncondensing
Altitude 1000m
Altitude derating (>1000m) -1% per 100m; 3000m max.
DRIVE PROTECTION
Supply loss Input phase loss
Software thermal model Heatsink overheat
IGBT overload Internal air overheat
Output current limit Output current trip
DC bus voltage limiting  
Short circuited load Ground fault
Low DC bus voltage Regeneration limit
Hardware failure  
MOTOR AND DYNAMIC BRAKE PROTECTION
Motor thermal model trip PTC thermistor trip
Overload warning Shear pin trip (configurable)
Dynamic brake resistor thermal model trip
Torque limit and time-out (configurable)
Speed limit and time-out (configurable)
CONTROL
Control method Flux vector or V/Hz control
Analogue inputs 2 inputs, configurable as 0-10 Vdc,
±10Vdc, 4-20mA or 0-20mA
Digital inputs 6 configurable inputs plus 1 PTC or trip input
Analogue outputs 2 outputs, configurable as 0-10Vdc, ±10Vdc, 4-20mA or 0-20mA
Relay outputs 1 changeover, 2 normally open, rated 250Vac or 30Vdc, 2A non-inductive.

 
DIMENSIONS
Item Reference H
mm (ins)
W
mm (ins)
D
mm (ins)
Weight
kg (lbs)
E002 430 (16.9) 139 (5.5) 262 (10.3) 10-14 (22-31)
E006 430 (16.9) 139 (5.5) 262 (10.3) 10-14 (22-31)
E010 430 (16.9) 139 (5.5) 262 (10.3) 10-14 (22-31)
E012 430 (16.9) 139 (5.5) 262 (10.3) 10-14 (22-31)
E018 430 (16.9) 139 (5.5) 262 (10.3) 10-14 (22-31)
E022 430 (16.9) 139 (5.5) 262 (10.3) 10-14 (22-31)
E031 430 (16.9) 279 (11) 262 (10.3) 27 (59.5)
E038 430 (16.9) 279 (11) 262 (10.3) 27 (59.5)
E046 430 (16.9) 279 (11) 262 (10.3) 27 (59.5)

 

Model Selection Guide

One drive fits all applications
Exceptional Performance
Suitable for harsh industrial environments
Installation Flexibility
Control Flexibility
Certified and Approved CE
Elite transplant means new life for stadium construction crane
Applications
 
Product Overview
 
Support Documentation

 

 

 

 

 

Enclosure
Rating
Frame Item Reference 380-440V (Note 1) Recommended Cable
Sizing per Phase
Fuses
I[A] @ 50°C
(Note 2)

Motor kW
@ 400V 50
°C
(Note 3)

I[A] @ 40°C
F > 25Hz
(Note 4)
AWG/kcmil mm2 A
(Note 5)
Nema 12 
and
Nema 1 
models
available
1 E002 2.5 0.75 3.1 14 to 12  2.5 to 4 6
E006 6.5 3 8.1 12 to 10 2.5 to 4 16
E010 10.5 4 13.1 12 to 10 2.5 to 4 25
E012 12 5.5 15 10 to 8 4 to 6 32
IEC IP54 
and
IP20 models
available
2 E018 18 7.5 22.5 10 to 8 4 to 6 40
E022 22.5 11 28 10 to 8 4 to 6 50
3 E031 31 15 39 8 to 6 6 to 10 80
E038 38 18.5 47 6 to 4 10 to 16 100
E046 46 22 57 4 to 3 16 to 25 100

Note 1: Frame sizes 1-3 are also available to suit a 230Vac (-20+10%) supply.
Note 2: Current ratting is constant across the voltabe range.
Note 3: Power rating applies to typical 4-pole machines only. Check your motor specification before
           selecting.
Note 4: Decrease Linearly to nominal at 0Hz. 
Note 5: Fuse must be selected to protect circuits with a maximum 200kA symmetrical short circuit
           supply.